This brake is available in the following versions:
Frame size 63 - 160 all pole configurations
Frame size180 - 225 only 4, 6 or 8 poles
or 2-poles S3 40%
Frame size 250 - 280 only 4, 6, 8 poles
Terminal box Ex d
5 to 1200 Nm depending on frame size (for standard
assignments, see page 107)
24 to 690 VAC 1~, 50/60 Hz,
(for brake sizes 80 to 160 also 3~) 24 to 300 VDC
Category 2 G / 2D / 2GD
Protection type Ex d / Ex tb
Protection group IIB / IIC
Temperature class T3 / T4 / T5
maximum surface temperature T200°C / T135°C /
T100°C
Protection type IP66
Ambient temperature -20 to +40 °C / -50 to +55 °C
thermal protection by means of thermo switch (in
addition, PTC thermistor as an option)
Manual ventilation (optional; not for 250/280)
Micro switch (optional)
Anti-condensation heater (optional)
Special flanges or shafts on request
This brake is always attached to a reinforced fan cowl on
the non-drive side of the motor. Properties:
Frame sizes 80 to 200
Terminal compar tment Ex e
10 to 270 Nm depending on frame size (for standard
assignment, see page 106)
110 to 400 VAC 1~, 50/60 Hz 12 up to 356VDC
Category 2 G / 2D / 2GD
Protection type Ex de / Ex tb
Protection group IIC
Temperature class T5
Maximum surface temperature T100°C
Protection type IP67
Ambient temperature -20 °C to +40 °C
Thermal protection by means of thermo switch
Manual ventilation (optional)
Micro switch (optional)
Three-phase AC Asynchronous Motors with Integrated Frequency Inverter
Frame sizes 80 to 160
Supply voltage 380 to 500 V ±10 %, 50/60 Hz
Range of power 0,55 bis 11 kW
Maximum current 150 % In for 60 s in 10 min
Leakage current to PE > 3,5 mA
(to EN 50178) Fixed installations required
Fixed installations required double PE
Output frequency 2 to 50/100 Hz
Frequency resolution absolute 0,02 Hz
High-Voltage Motors
–Series CD 355...H to CD 450...H
–Acceptance for category II 2G for use in zones 1 and 2
–Acceptance for category II 2G for use in zones 21 and 22
–Temperature classes T3 to T6
–Power range from 160 to approx. 700 kW (for 1500 rpm)
–Rated voltage from 3 kV to 6.6 kV
–50Hz for 2 to 8 poles, 60 Hz for 4 to 8 poles
–Self-cooling (IC411) with fans which are independent
of the direction of rotation
–Low-noise design with axial fans which are dependent
of the direction of rotation
–Anti-condensation heater
–Low temperature up to -55 °C without heater
–Ambient temperatures of up to 60 °C
–Altitude of installation above 1000 m m.s.l.
-Installation of temperature sensors such as PT 100,
PTC thermistors or KTY in winding and bearing for
additional protection
–Customer-specific special-purpose versions